PA
IR Size: 8x10 LW
SID: 40""
Page #'s: 2:344,306
|
Positioning:
Pt seated or prone
Forehead & nose on grid
|
CR Entrance & Angle:
CR exits Acanthion
Collimation:
Close
Respiration:
Suspend
Best to Determine:
Entire mandible
Mandibular rami & body
|
Eval Criteria:
Primarily used to demonstrate medial/lateral displacement of fragments or fracture in the rami
NR by symmetric rami & body bilaterally
|
|
PA axial
IR Size: 8x10 LW
SID: 40""
Page #'s: 2:345,308
|
Positioning:
Pt seated or prone
Forehead & nose on grid
(Like PA but angle + condylar processes)
|
CR Entrance & Angle:
CR exits Acanthion
20°-25° cephalic
Collimation:
Close
Respiration:
Suspend
Best to Determine:
Mandible & Condylar processes
Mandibular rami & body
|
Anatomy to IR:
MSP centered to IR & OML _|_ to IR, Acanthion to crosshairs
Eval Criteria:
Primarily used to demonstrate medial/lateral displacement of fragments or fracture in the rami
NR by symmetric rami & body bilaterally
|
|